https://wiki.securifi.com/api.php?action=feedcontributions&user=SecureComp&feedformat=atom
SecuriWiki - User contributions [en]
2024-03-28T11:42:35Z
User contributions
MediaWiki 1.22.4
https://wiki.securifi.com/index.php?title=List_of_compatible_sensors_-_Almond%2B_2014
List of compatible sensors - Almond+ 2014
2016-02-26T19:14:23Z
<p>SecureComp: /* Z-Wave */</p>
<hr />
<div>[[Category:Almond+ 2014]]<br />
[[Category:Sensors]]<br />
This is a lists of sensors and devices that are known to work with the [[Almond+ 2014]] and have been tested by Securifi, as well as sensors and devices tested by our customers and found to be working, but that haven't been verified by Securifi.<br /><br />
If you tried a device that is not listed, please let us know on the [http://forum.securifi.com/ forum].<br />
<br />
=== ZigBee ===<br />
<br />
{| class="wikitable sortable"<br />
|-<br />
! Manufacturer !! Model name !! Type !! Technology !! User tested !! Verified by Securifi !! Comments !! Date added <br />
|-<br />
| Securifi || [[Securifi SZ-DWS02|SZ-DWS02]] || Door/Window magnetic reed sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-PIR02|SZ-PIR02]] || PIR motion detector || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-BSW01|SZ-BSW01]] || Binary on/off plug-in switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Only provided to Kickstarter developer and beta backers||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-ESW01|SZ-ESW01]] || Power monitoring switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Only provided as a limited upgrade option to Kickstarter backers||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-WTD01|SZ-WTD01]] || Flood sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-KFB01|SZ-KFB01]] || Key fob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jun 2014<br />
|-<br />
| Securifi || [[Securifi Peanut Plug PP1-WHT-US|Peanut Plug]] || Power monitoring switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Note that the power monitoring will be added via an OTA firmware update||Jan 2015<br />
|-<br />
| Osram/Sylvania || [[Osram_Sylvania Ultra iQ|Ultra iQ]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||May 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SGB02|WZB-SGB02]] || Vibration sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SMG02|WZB-SMG02]] || Door/Window magnetic reed sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SSM706|WZB-SSM706]] || Smoke detector || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Fortrezz || [[SmartSense Moisture|SmartSense Moisture]] || Moisture sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||<br />
|-<br />
| GE || [[GE/Wink Link bulbs|GE/Wink Link bulbs]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||<br />
|-<br />
| SmartThings || [[SmartThings SmartSense Multi Sensor|SmartSense Multi Sensor]] || Door/Window multi sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Trigger the sensor once to make it connect to the Almond+ during the adding process NOTE: Reports Open/Close Does NOT Report Temp/Vibration/Angle||<br />
|-<br />
| Belkin || [[WeMo Smart LED bulb|WeMo Smart LED bulb]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2015<br />
|-<br />
| Philips || [[Philips hue hub|hue hub]] || hue light hub || [[File:Zigb.png]] - ZigBee || Yes || Yes ||The hub has to be paired with the Almond+ to control the bulbs though the Almond app||Feb 2015<br />
|-<br />
| Cree || [[Cree Connected Smart Bulb|Cree Connected Smart Bulb]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || No ||Home Depot exclusive||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Door & Window Sensor|CentraLite 3-Series Door & Window Sensor]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Water Sensors|CentraLite 3-Series Water Sensors]] || Flood sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Temp and Humidity Sensor|CentraLite 3-Series Temp & Humidity Sensor]] || Temperature and humidity sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq. Note that humidity sensing is currently unsupported||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Motion Sensor|CentraLite 3-Series Motion Sensor]] || Motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq. ||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3011|NCZ-3011]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3014|NCZ-3014]] || Garage Door (Tilt) Sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3041|NCZ-3041]] || Motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3043|NCZ-3043]] || Ceiling motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3202|NCZ-3202]] || Lifestyle automation keyfob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3201|NCZ-3201]] || Access control keyfob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Classic A60 RGBW|Lightify Classic A60 RGBW]] || RGBW LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Classic A60 tunable white|Lightify Classic A60 tunable white]] || Tunable white LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify PAR16 50 tunable white|Lightify PAR16 50 tunable white]] || Tunable white LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Surface light tunable white|Lightify Surface light tunable white]] || Tunable white LED light || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Quirky/GE || [[Quirky PTRPR-WH01|Quirky + GE Tripper]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Quirky/GE || [[Quirky PTAPT-WH02|Quirky + GE Tapt ]] || Smart wall switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Yale || [[Yale YRD-220-HA-619|YRD-220-HA-619]] || Deadbolt Lock || [[File:Zigb.png]] - ZigBee || Yes || Yes || Only lock/unlock ||<br />
|-<br />
|}<br />
<br />
=== Z-Wave ===<br />
<br />
Z-wave frequency changes from region to region and Z-wave sensor of one region, can be added only to that particular region controller and not to any other region controller (Example: US Z-wave frequency sensor could be added only to US Z-wave frequency controller). <br />
<br />
{| class="wikitable sortable"<br />
|-<br />
! Manufacturer !! Model name !! Type !! Technology !! User tested !! Verified by Securifi !! Comments !! Date added <br />
|-<br />
| Vision || [[Vision ZD2102|ZD2102]] || Door/Window magnetic reed sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZL7201|ZL7201]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZL7101|ZL7101]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZM1701|ZM1701]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision ZM1702|ZM1702]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ5101|ZS5101]] || Shock sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ3102|ZS3102]] || PIR motion sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ6101|ZS6101]] || Smoke Detector || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Fibaro || [[Fibaro FGK-101-107]] || Door/Window sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes || No extra features ||<br />
|-<br />
| Fibaro || [[Fibaro FGWPE/F-101]] || Wall plug || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only On/Off and power reading ||<br />
|-<br />
| Fibaro || [[Fibaro FGFS-101]] || Flood sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only flood alert so far ||<br />
|-<br />
| Fibaro || [[Fibaro FGMS-001]] || Multi sensor || [[File:Zwave.png]] - Z-Wave || Yes || No || Motion, Temperature, Luminance ||<br />
|-<br />
| Yale || [[Yale YRD210|YRD210]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Schlage || [[Schlage FE599|FE599]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Schlage || [[Schlage BE369|BE369]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || No || Only lock/unlock & user code ||<br />
|-<br />
| Lowe's Iris || [[Lowe's Iris CT100|CT100]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Lowe's Iris || [[Lowe's Iris CT101|CT101]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| 2Gig Technologies || [[2Gig Technologies CT30|CT30]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| 2Gig Technologies || [[2Gig Technologies RTZW-01|RTZW-01]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| First Alert || [[First Alert Smoke & CO Detectors|ZSMOKE]] || Smoke Detector || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| First Alert || [[First Alert Smoke & CO Detectors|ZCOMBO]] || Smoke and CO Detector || [[File:Zwave.png]] - Z-Wave || Yes || No || CO events may not be shown ||<br />
|-<br />
| Poly-Control || [[Poly-Control Danalock|Danalock]] || Door lock ||[[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock ||<br />
|-<br />
| Intermatic Home Settings || [[HA01]] || In-Wall receptacle || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring AN158|AN158]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring AD142|AD142]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring ST812|ST812]] || Flood sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring SE812|SE812]] || Siren with Red Strobe/Flashing LED|| [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| GE/Jasco || [[GE 45603|ZW4101/45603]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| GE/Jasco || [[GE 45604|45604]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes || For Outdoors use ||<br />
|-<br />
| GE || [[GE ZW3101|ZW3101]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Remotec || [[Remotec ZDS-100|ZDS-100]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Remotec || [[Remotec ZFM-80|ZFM-80]] || Binary on/off switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Trane || [[Trane TZEMT400BB3NX|TZEMT400BB3NX ]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| GE || [[GE 45605|GE 45605]] || Duplex Receptacle || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Yale || [[Yale YRD220-ZW-ORB|YRD220-ZW-ORB]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || No || Only lock/unlock & user code ||<br />
|-<br />
| Jasco || [[Jasco 45609|45609]] || Wireless Lighting Control On/Off Switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Leviton || [[Leviton VRS15-1LZ Vizia RF|VRS15-1LZ Vizia RF]] || Binary on/off light switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Leviton || [[Leviton DZMX1]] || Dimmer light switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||Was required to remove device prior to almond pair. Pair as multilevel switch||Aug 2015 <br />
|-<br />
| Intermatic || [[HomeSettings HA05|HA05]] || Binary on/off Screw-In Lamp module || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Kwikset || [[Kwikset 910TRL ZW|Kwikset 910TRL ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Kwikset || [[Kwikset 910CNT ZW|Kwikset 910CNT ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Kwikset || [[Kwikset 914TRL ZW|Kwikset 914TRL ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Danfoss || [[Living Connect LC-13|Living Connect LC-13]] || Setpoint radiator thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Nov 2014<br />
|-<br />
| Linear/LinearLinc || [[Linear Bulbz LB60Z|Bulbz LB60Z]] || Dimmable LED bulb || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||Added as a dimmer rather than a light bulb||Jan 2015<br />
|-<br />
| Aeon Labs || [[DSB29-ZWUS|Door & Window Sensor - 2nd Edition]] || Door & Window Sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| Aeon Labs || [[DSC24-ZWUS|Plug-in Smart Appliance Switch]] || Power monitoring switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| GE/Jasco || [[GE 45609LAB|ZW4001/45609LAB]] || In-wall binary on/off switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| Remotec || [[Remotec ZDS-200|ZDS-200]] || Selectable plug-in dimmer/binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZFM-X10|ZFM-X10]] || Selectable in-wall dimmer/binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZRM-M80DE|ZRM-M80DE]] || Selectable plug-in dimmer/binary switch with CEE7/4 plug || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Vision || [[Vision ZL-7431|ZL-7431]] || In-wall binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||Single relay only||Feb 2015<br />
|-<br />
| Vision || [[Vision ZL-7433|ZL-7433]] || In-wall dimmer || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Linear || [[Linear WD500Z-1|WD500Z-1]] || Hard Wired Wall Mount Dimmer Switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||March 2015<br />
|-<br />
| Vision || [[Vision ZG8101|ZG8101]] || Tilt/garage door sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink ECO-TILT-US|ECO-TILT-US]] || Tilt/garage door sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink PIRZWAVE2-ECO|PIRZWAVE2-ECO]] || PIR motion sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink DWZWAVE2-ECO|DWZWAVE2-ECO]] || Door/Window sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Leviton || [[Leviton DZS15-1L|Vizia rf+ DZS15-1L]] || Hard wired wall mounted switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Secure Together || [[Secure SRT321|SRT321]] || Set-point thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Utilitech || [[Utilitech TSE07-1|TSE07-1]] || Siren with Red Strobe/Flashing LED || [[File:Zwave.png]] - Z-Wave || Yes || No |||||June 2015<br />
|-<br />
| Everspring || [[AN180-6|AN180-6]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No || ON/OFF ||<br />
|-<br />
| Everspring || [[AD146|AD146]] || Switch || [[File:Zwave.png]] - Z-Wave || Yes || No || ON/OFF ||<br />
|-<br />
| Monoprice || [[11987|11987]] || Garage Door Sensor || [[File:Zwave.png]] - Z-Wave || Yes || No || ON/OFF ||</div>
SecureComp
https://wiki.securifi.com/index.php?title=DSC24-ZWUS
DSC24-ZWUS
2015-06-25T18:39:13Z
<p>SecureComp: </p>
<hr />
<div>'''Aeon Labs DSC06106-ZWUS - Z-Wave Smart Energy Switch'''<br />
<br />
* Pairs with Almond+ 2014 R80, no issues.<br />
* Android App Rev 4.2 Reports On/Off Status and Power Usage while On<br />
* IOS App Reports 1.5 On/Off Status and Power Usage while On<br />
* LCD Reports On/Off Status and Power Usage while On<br />
* Web User Interface Reports On/Off Status and Power Usage while On<br />
* Cloud User Interface Reports On/Off Status and Power Usage while On<br />
<br />
The Aeon Labs Smart Energy Switch ''works as a Z-Wave Repeater'', typical of Z-Wave devices that are A/C powered.<br />
<br />
* The switch itself has a blue LED switch for manual powering On/Off.<br />
* '''If the Blue LED is blinking, it is not paired with any system.'''<br />
<br />
More information available on the forums.<br />
http://forum.securifi.com/index.php/topic,3441.0.html</div>
SecureComp
https://wiki.securifi.com/index.php?title=DSC24-ZWUS
DSC24-ZWUS
2015-06-25T18:13:41Z
<p>SecureComp: Brief description of Aeon Labs DSC06106 SES</p>
<hr />
<div>'''Aeon Labs DSC06106-ZWUS - Z-Wave Smart Energy Switch'''<br />
<br />
* Pairs with Almond+ 2014 R80, no issues.<br />
* Android App Rev 4.2 Reports On/Off Status and Power Usage while On<br />
* IOS App Reports 1.5 On/Off Status and Power Usage while On<br />
* LCD Reports On/Off Status and Power Usage while On<br />
<br />
The Aeon Labs Smart Energy Switch ''works as a Z-Wave Repeater'', typical of Z-Wave devices that are A/C powered.<br />
<br />
* The switch itself has a blue LED switch for manual powering On/Off.<br />
* '''If the Blue LED is blinking, it is not paired with any system.'''<br />
<br />
More information available on the forums.<br />
http://forum.securifi.com/index.php/topic,3441.0.html</div>
SecureComp
https://wiki.securifi.com/index.php?title=Simple_Switch_App
Simple Switch App
2015-06-23T03:37:42Z
<p>SecureComp: </p>
<hr />
<div>[[Category:Almond+ 2014]]<br />
The code in [[SDK_Setup_Guide_-_Almond+_2014]] for the sample switch app does not quite work as is, but the adjustment is fairly simple. Replace the main function with the following (note ~2 differences):<br />
<br />
switch.cpp:<br />
<code><pre><br />
main(int argc, char **argv) {<br />
<br />
HADevices::initialize();<br />
HADevices::genericCallback(&callback);<br />
<br />
if(argc <= 1 || argc >3)<br />
{<br />
//print usage<br />
fprintf(stderr, "usage: ./almond/switch Devid state\n");<br />
fprintf(stderr, " ./almond/switch <DevID> <1/0>\n");<br />
fprintf(stderr, "* example to turn on switch with DevId 2 : ./almond/switch 2 1\n");<br />
fprintf(stderr, "* go to device manager to see switch DevID ex: sensor #devid\n");<br />
fprintf(stderr, "* execute binary from / directory\n");<br />
return -1;<br />
}<br />
<br />
HADevices * ha = new HADevices;<br />
Device *sw;<br />
<br />
try {<br />
sw = ha->getDeviceByID(1);<br />
printf("Device %d found with name %s\n", sw->getID(), sw->getDeviceName());<br />
}catch (int exeption) {<br />
printf("No device found with that devid\n");<br />
return -1;<br />
}<br />
if(atoi(argv[2]))<br />
{<br />
fprintf(stderr, "Toggling switch on");<br />
sw->setSwitchOn(true);<br />
}<br />
else<br />
{<br />
fprintf(stderr, "Toggling switch off");<br />
sw->setSwitchOn(false);<br />
}<br />
<br />
while (1) {<br />
pause();<br />
}<br />
}<br />
</pre></code><br />
<br />
In order to resolve an "atoi" error during compile, add two more includes, stdio.h and stdlib.h.<br />
The complete modified switch.cpp file is shown below.<br />
<br />
<code><pre><br />
// add these 2 includes to avoid atoi error<br />
#include <stdio.h><br />
#include <stdlib.h><br />
<br />
#include <stdarg.h><br />
#include <iostream><br />
#include <string><br />
#include <string.h><br />
#include <fstream><br />
#include <sstream><br />
#include <sys/file.h><br />
#include <errno.h><br />
#include <fcntl.h><br />
#include <unistd.h><br />
#include <libAlmondHA.h><br />
<br />
void callback(Device* dev);<br />
//replace main proc with this new main proc from securifi wiki<br />
main(int argc, char **argv) {<br />
<br />
HADevices::initialize();<br />
HADevices::genericCallback(&callback);<br />
<br />
if(argc <= 1 || argc >3)<br />
{<br />
//print usage<br />
fprintf(stderr, "usage: ./almond/switch Devid state\n");<br />
fprintf(stderr, " ./almond/switch <DevID> <1/0>\n");<br />
fprintf(stderr, "* example to turn on switch with DevId 2 : ./almond/switch 2 1\n");<br />
fprintf(stderr, "* go to device manager to see switch DevID ex: sensor #devid\n");<br />
fprintf(stderr, "* execute binary from / directory\n");<br />
return -1;<br />
}<br />
<br />
HADevices * ha = new HADevices;<br />
Device *sw;<br />
<br />
try {<br />
sw = ha->getDeviceByID(1);<br />
printf("Device %d found with name %s\n", sw->getID(), sw->getDeviceName());<br />
}catch (int exeption) {<br />
printf("No device found with that devid\n");<br />
return -1;<br />
}<br />
if(atoi(argv[2]))<br />
{<br />
fprintf(stderr, "Toggling switch on");<br />
sw->setSwitchOn(true);<br />
}<br />
else<br />
{<br />
fprintf(stderr, "Toggling switch off");<br />
sw->setSwitchOn(false);<br />
}<br />
<br />
while (1) {<br />
pause();<br />
}<br />
}<br />
<br />
void callback(Device* dev) {<br />
fprintf(stderr, "Device Created Callback: %s\n",dev->getDeviceName());<br />
fprintf(stderr, "Index: %s, Value: %s\n", dev->getLastNotificationIndexName(), dev->getLastNotificationIndexValue());<br />
}<br />
<br />
<br />
</pre></code><br />
<br />
Here is a version with all changes made to allow for command line input as well as console output of the callback info. Comments included.<br />
<br />
<code><pre><br />
// add 2 more includes to fix atoi compile error<br />
// using atoi allows you to process command line variables<br />
// if you are hardcoding device information you do not need atoi and can eliminate the sdtio and stdlib includes<br />
#include <stdio.h><br />
#include <stdlib.h><br />
<br />
#include <stdarg.h><br />
#include <iostream><br />
#include <string><br />
#include <string.h><br />
#include <fstream><br />
#include <sstream><br />
#include <sys/file.h><br />
#include <errno.h><br />
#include <fcntl.h><br />
#include <unistd.h><br />
#include <libAlmondHA.h><br />
<br />
//function callback Device Name and Device ID<br />
void callback(Device* dev);<br />
<br />
//function main<br />
main(int argc, char **argv) {<br />
<br />
// Home Automation Device Call - initialize and execute callback<br />
HADevices::initialize();<br />
HADevices::genericCallback(&callback);<br />
<br />
// catch error for less than 1 or more than 2 command line parameters, argc is the actual number of command line inputs<br />
if(argc <= 1 || argc >3)<br />
{<br />
<br />
//print usage description on error catch<br />
fprintf(stderr, "usage: ./almond/switch Devid state\n");<br />
fprintf(stderr, " ./almond/switch <DevID> <1/0>\n");<br />
fprintf(stderr, "* example to turn on switch with DevId 2 : ./almond/switch 2 1\n");<br />
fprintf(stderr, "* go to device manager to see switch DevID ex: sensor #devid\n");<br />
fprintf(stderr, "* execute binary from / directory\n");<br />
return -1;<br />
}<br />
<br />
// Set Device ID prior to executing On/Off command<br />
Device *sw;<br />
<br />
// verify that Device ID is valid before proceessing on/off set command<br />
// try catch statement performs check to verify valid Device ID and errors out if not found<br />
try {<br />
sw = new Device(atoi(argv[1]));<br />
}catch (int exeption) {<br />
printf("No device found with that devid\n");<br />
return -1;<br />
}<br />
<br />
// if then else block to process Switch On or Off<br />
// using atoi to use command line input, you could just hardcode a Device ID here if you were working with a specific device with your app<br />
// if the 2nd command line input variable is 1, set switch to On else set to Off<br />
if(atoi(argv[2]))<br />
{<br />
sw->setSwitchOn(true);<br />
}<br />
else<br />
{<br />
sw->setSwitchOn(false);<br />
}<br />
// while true<br />
while (1) {<br />
pause();<br />
}<br />
}<br />
<br />
// The code below will provide a constant callback update to the console of any actions to the device class selected<br />
// You will have to interrupt the output using CTRL-C to stop execution<br />
<br />
<br />
// callback Device Name and Device ID with info from Device<br />
void callback(Device* dev) {<br />
// Display name of Device that is providing callback info<br />
fprintf(stderr, "Device Created Callback: %s\n",dev->getDeviceName());<br />
// Display Last Notification Index Name and Value for Device<br />
fprintf(stderr, "Index: %s, Value: %s\n", dev->getLastNotificationIndexName(), dev->getLastNotificationIndexValue());<br />
}<br />
</pre></code></div>
SecureComp
https://wiki.securifi.com/index.php?title=Simple_Switch_App
Simple Switch App
2015-06-23T02:44:20Z
<p>SecureComp: added comments to sample app, fixed argc and argv issues</p>
<hr />
<div>[[Category:Almond+ 2014]]<br />
The code in [[SDK_Setup_Guide_-_Almond+_2014]] for the sample switch app does not quite work as is, but the adjustment is fairly simple. Replace the main function with the following (note ~2 differences):<br />
<br />
switch.cpp:<br />
<code><pre><br />
main(int argc, char **argv) {<br />
<br />
HADevices::initialize();<br />
HADevices::genericCallback(&callback);<br />
<br />
if(argc <= 1 || argc >3)<br />
{<br />
//print usage<br />
fprintf(stderr, "usage: ./almond/switch Devid state\n");<br />
fprintf(stderr, " ./almond/switch <DevID> <1/0>\n");<br />
fprintf(stderr, "* example to turn on switch with DevId 2 : ./almond/switch 2 1\n");<br />
fprintf(stderr, "* go to device manager to see switch DevID ex: sensor #devid\n");<br />
fprintf(stderr, "* execute binary from / directory\n");<br />
return -1;<br />
}<br />
<br />
HADevices * ha = new HADevices;<br />
Device *sw;<br />
<br />
try {<br />
sw = ha->getDeviceByID(1);<br />
printf("Device %d found with name %s\n", sw->getID(), sw->getDeviceName());<br />
}catch (int exeption) {<br />
printf("No device found with that devid\n");<br />
return -1;<br />
}<br />
if(atoi(argv[2]))<br />
{<br />
fprintf(stderr, "Toggling switch on");<br />
sw->setSwitchOn(true);<br />
}<br />
else<br />
{<br />
fprintf(stderr, "Toggling switch off");<br />
sw->setSwitchOn(false);<br />
}<br />
<br />
while (1) {<br />
pause();<br />
}<br />
}<br />
</pre></code><br />
<br />
In order to resolve an "atoi" error during compile, add two more includes, stdio.h and stdlib.h.<br />
The complete modified switch.cpp file is shown below.<br />
<br />
<code><pre><br />
// add these 2 includes to avoid atoi error<br />
#include <stdio.h><br />
#include <stdlib.h><br />
<br />
#include <stdarg.h><br />
#include <iostream><br />
#include <string><br />
#include <string.h><br />
#include <fstream><br />
#include <sstream><br />
#include <sys/file.h><br />
#include <errno.h><br />
#include <fcntl.h><br />
#include <unistd.h><br />
#include <libAlmondHA.h><br />
<br />
void callback(Device* dev);<br />
//replace main proc with this new main proc from securifi wiki<br />
main(int argc, char **argv) {<br />
<br />
HADevices::initialize();<br />
HADevices::genericCallback(&callback);<br />
<br />
if(argc <= 1 || argc >3)<br />
{<br />
//print usage<br />
fprintf(stderr, "usage: ./almond/switch Devid state\n");<br />
fprintf(stderr, " ./almond/switch <DevID> <1/0>\n");<br />
fprintf(stderr, "* example to turn on switch with DevId 2 : ./almond/switch 2 1\n");<br />
fprintf(stderr, "* go to device manager to see switch DevID ex: sensor #devid\n");<br />
fprintf(stderr, "* execute binary from / directory\n");<br />
return -1;<br />
}<br />
<br />
HADevices * ha = new HADevices;<br />
Device *sw;<br />
<br />
try {<br />
sw = ha->getDeviceByID(1);<br />
printf("Device %d found with name %s\n", sw->getID(), sw->getDeviceName());<br />
}catch (int exeption) {<br />
printf("No device found with that devid\n");<br />
return -1;<br />
}<br />
if(atoi(argv[2]))<br />
{<br />
fprintf(stderr, "Toggling switch on");<br />
sw->setSwitchOn(true);<br />
}<br />
else<br />
{<br />
fprintf(stderr, "Toggling switch off");<br />
sw->setSwitchOn(false);<br />
}<br />
<br />
while (1) {<br />
pause();<br />
}<br />
}<br />
<br />
void callback(Device* dev) {<br />
fprintf(stderr, "Device Created Callback: %s\n",dev->getDeviceName());<br />
fprintf(stderr, "Index: %s, Value: %s\n", dev->getLastNotificationIndexName(), dev->getLastNotificationIndexValue());<br />
}<br />
<br />
<br />
</pre></code><br />
<br />
Here is a version with all changes made to allow for command line input as well as console output of the callback info. Comments included.<br />
<br />
<code><pre><br />
// add 2 more includes to fix atoi compile error<br />
// using atoi allows you to process command line variables<br />
// if you are hardcoding device information you do not need atoi and can eliminate the sdtio and stdlib includes<br />
#include <stdio.h><br />
#include <stdlib.h><br />
<br />
#include <stdarg.h><br />
#include <iostream><br />
#include <string><br />
#include <string.h><br />
#include <fstream><br />
#include <sstream><br />
#include <sys/file.h><br />
#include <errno.h><br />
#include <fcntl.h><br />
#include <unistd.h><br />
#include <libAlmondHA.h><br />
<br />
//function callback Device Name and Device ID<br />
void callback(Device* dev);<br />
<br />
//function main<br />
main(int argc, char **argv) {<br />
<br />
// Home Automation Device Call - initialize and execute callback<br />
HADevices::initialize();<br />
HADevices::genericCallback(&callback);<br />
<br />
// catch error for less than 1 or more than 2 command line parameters, argc is the actual number of command line inputs<br />
if(argc <= 1 || argc >3)<br />
{<br />
<br />
//print usage description on error catch<br />
fprintf(stderr, "usage: ./almond/switch Devid state\n");<br />
fprintf(stderr, " ./almond/switch <DevID> <1/0>\n");<br />
fprintf(stderr, "* example to turn on switch with DevId 2 : ./almond/switch 2 1\n");<br />
fprintf(stderr, "* go to device manager to see switch DevID ex: sensor #devid\n");<br />
fprintf(stderr, "* execute binary from / directory\n");<br />
return -1;<br />
}<br />
<br />
// Set Device ID prior to executing On/Off command<br />
Device *sw;<br />
<br />
// verify that Device ID is valid before proceessing on/off set command<br />
// try catch statement performs check to verify valid Device ID and errors out if not found<br />
try {<br />
sw = new Device(atoi(argv[1]));<br />
}catch (int exeption) {<br />
printf("No device found with that devid\n");<br />
return -1;<br />
}<br />
<br />
// if then else block to process Switch On or Off<br />
// using atoi to use command line input, you could just hardcode a Device ID here if you were working with a specific device with your app<br />
// if the 2nd command line input variable is 1, set switch to On else set to Off<br />
if(atoi(argv[2]))<br />
{<br />
sw->setSwitchOn(true);<br />
}<br />
else<br />
{<br />
sw->setSwitchOn(false);<br />
}<br />
// while true<br />
while (1) {<br />
pause();<br />
}<br />
}<br />
<br />
// The code below will provide a constant callback update to the console of any actions to the device class selected<br />
// You will have to interrupt the output using CTRL-C to stop execution<br />
// Comment out the below code if you do not want to see Device Status callbacks<br />
<br />
// callback Device Name and Device ID with info from Device<br />
void callback(Device* dev) {<br />
// Display name of Device that is providing callback info<br />
fprintf(stderr, "Device Created Callback: %s\n",dev->getDeviceName());<br />
// Display Last Notification Index Name and Value for Device<br />
fprintf(stderr, "Index: %s, Value: %s\n", dev->getLastNotificationIndexName(), dev->getLastNotificationIndexValue());<br />
}<br />
</pre></code></div>
SecureComp
https://wiki.securifi.com/index.php?title=List_of_compatible_sensors_-_Almond%2B_2014
List of compatible sensors - Almond+ 2014
2015-06-22T05:24:21Z
<p>SecureComp: /* ZigBee */</p>
<hr />
<div>[[Category:Almond+ 2014]]<br />
[[Category:Sensors]]<br />
This is a lists of sensors and devices that are known to work with the [[Almond+ 2014]] and have been tested by Securifi, as well as sensors and devices tested by our customers and found to be working, but that haven't been verified by Securifi.<br /><br />
If you tried a device that is not listed, please let us know on the [http://forum.securifi.com/ forum].<br />
<br />
=== ZigBee ===<br />
<br />
{| class="wikitable sortable"<br />
|-<br />
! Manufacturer !! Model name !! Type !! Technology !! User tested !! Verified by Securifi !! Comments !! Date added <br />
|-<br />
| Securifi || [[Securifi SZ-DWS02|SZ-DWS02]] || Door/Window magnetic reed sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-PIR02|SZ-PIR02]] || PIR motion detector || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-BSW01|SZ-BSW01]] || Binary on/off plug-in switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Only provided to Kickstarter developer and beta backers||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-ESW01|SZ-ESW01]] || Power monitoring switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Only provided as a limited upgrade option to Kickstarter backers||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-WTD01|SZ-WTD01]] || Flood sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-KFB01|SZ-KFB01]] || Key fob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jun 2014<br />
|-<br />
| Securifi || [[Securifi Peanut Plug PP1-WHT-US|Peanut Plug]] || Power monitoring switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Note that the power monitoring will be added via an OTA firmware update||Jan 2015<br />
|-<br />
| Osram/Sylvania || [[Osram_Sylvania Ultra iQ|Ultra iQ]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||May 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SGB02|WZB-SGB02]] || Vibration sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SMG02|WZB-SMG02]] || Door/Window magnetic reed sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SSM706|WZB-SSM706]] || Smoke detector || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Fortrezz || [[SmartSense Moisture|SmartSense Moisture]] || Moisture sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||<br />
|-<br />
| GE || [[GE/Wink Link bulbs|GE/Wink Link bulbs]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||<br />
|-<br />
| SmartThings || [[SmartThings SmartSense Multi Sensor|SmartSense Multi Sensor]] || Door/Window multi sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Trigger the sensor once to make it connect to the Almond+ during the adding process NOTE: Reports Open/Close Does NOT Report Temp/Vibration/Angle||<br />
|-<br />
| Belkin || [[WeMo Smart LED bulb|WeMo Smart LED bulb]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2015<br />
|-<br />
| Philips || [[Philips hue hub|hue hub]] || hue light hub || [[File:Zigb.png]] - ZigBee || Yes || Yes ||The hub has to be paired with the Almond+ to control the bulbs though the Almond app||Feb 2015<br />
|-<br />
| Cree || [[Cree Connected Smart Bulb|Cree Connected Smart Bulb]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || No ||Home Depot exclusive||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Door & Window Sensor|CentraLite 3-Series Door & Window Sensor]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Water Sensors|CentraLite 3-Series Water Sensors]] || Flood sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Temp and Humidity Sensor|CentraLite 3-Series Temp & Humidity Sensor]] || Temperature and humidity sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq. Note that humidity sensing is currently unsupported||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Motion Sensor|CentraLite 3-Series Motion Sensor]] || Motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq. ||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3011|NCZ-3011]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3014|NCZ-3014]] || Garage Door (Tilt) Sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3041|NCZ-3041]] || Motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3043|NCZ-3043]] || Ceiling motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3202|NCZ-3202]] || Lifestyle automation keyfob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3201|NCZ-3201]] || Access control keyfob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Classic A60 RGBW|Lightify Classic A60 RGBW]] || RGBW LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Classic A60 tunable white|Lightify Classic A60 tunable white]] || Tunable white LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify PAR16 50 tunable white|Lightify PAR16 50 tunable white]] || Tunable white LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Surface light tunable white|Lightify Surface light tunable white]] || Tunable white LED light || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Quirky/GE || [[Quirky PTRPR-WH01|Quirky + GE Tripper]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Quirky/GE || [[Quirky PTAPT-WH02|Quirky + GE Tapt ]] || Smart wall switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Yale || [[Yale YRD-220-HA-619|YRD-220-HA-619]] || Deadbolt Lock || [[File:Zigb.png]] - ZigBee || Yes || Yes || Only lock/unlock ||<br />
|-<br />
|}<br />
<br />
=== Z-Wave ===<br />
<br />
{| class="wikitable sortable"<br />
|-<br />
! Manufacturer !! Model name !! Type !! Technology !! User tested !! Verified by Securifi !! Comments !! Date added <br />
|-<br />
| Vision || [[Vision ZD2102|ZD2102]] || Door/Window magnetic reed sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZL7201|ZL7201]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZL7101|ZL7101]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZM1701|ZM1701]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision ZM1702|ZM1702]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ5101|ZS5101]] || Shock sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ3102|ZS3102]] || PIR motion sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ6101|ZS6101]] || Smoke Detector || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Fibaro || [[Fibaro FGK-101-107]] || Door/Window sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes || No extra features ||<br />
|-<br />
| Fibaro || [[Fibaro FGWPE/F-101]] || Wall plug || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only On/Off and power reading ||<br />
|-<br />
| Fibaro || [[Fibaro FGFS-101]] || Flood sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only flood alert so far ||<br />
|-<br />
| Yale || [[Yale YRD210|YRD210]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Schlage || [[Schlage FE599|FE599]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Schlage || [[Schlage BE369|BE369]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || No || Only lock/unlock & user code ||<br />
|-<br />
| Lowe's Iris || [[Lowe's Iris CT100|CT100]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Lowe's Iris || [[Lowe's Iris CT101|CT101]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| 2Gig Technologies || [[2Gig Technologies CT30|CT30]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| 2Gig Technologies || [[2Gig Technologies RTZW-01|RTZW-01]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| First Alert || [[First Alert Smoke & CO Detectors|ZSMOKE]] || Smoke Detector || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| First Alert || [[First Alert Smoke & CO Detectors|ZCOMBO]] || Smoke and CO Detector || [[File:Zwave.png]] - Z-Wave || Yes || No || CO events may not be shown ||<br />
|-<br />
| Poly-Control || [[Poly-Control Danalock|Danalock]] || Door lock ||[[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock ||<br />
|-<br />
| Intermatic Home Settings || [[HA01]] || In-Wall receptacle || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring AN158|AN158]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring AD142|AD142]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring ST812|ST812]] || Flood sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring SE812|SE812]] || Siren with Red Strobe/Flashing LED|| [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| GE/Jasco || [[GE 45603|ZW4101/45603]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| GE/Jasco || [[GE 45604|45604]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes || For Outdoors use ||<br />
|-<br />
| GE || [[GE ZW3101|ZW3101]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Remotec || [[Remotec ZDS-100|ZDS-100]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Remotec || [[Remotec ZFM-80|ZFM-80]] || Binary on/off switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Trane || [[Trane TZEMT400BB3NX|TZEMT400BB3NX ]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| GE || [[GE 45605|GE 45605]] || Duplex Receptacle || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Yale || [[Yale YRD220-ZW-ORB|YRD220-ZW-ORB]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || No || Only lock/unlock & user code ||<br />
|-<br />
| Jasco || [[Jasco 45609|45609]] || Wireless Lighting Control On/Off Switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Leviton || [[Leviton VRS15-1LZ Vizia RF|VRS15-1LZ Vizia RF]] || Binary on/off light switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Intermatic || [[HomeSettings HA05|HA05]] || Binary on/off Screw-In Lamp module || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Kwikset || [[Kwikset 910TRL ZW|Kwikset 910TRL ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Kwikset || [[Kwikset 910CNT ZW|Kwikset 910CNT ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Kwikset || [[Kwikset 914TRL ZW|Kwikset 914TRL ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Danfoss || [[Living Connect LC-13|Living Connect LC-13]] || Setpoint radiator thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Nov 2014<br />
|-<br />
| Linear/LinearLinc || [[Linear Bulbz LB60Z|Bulbz LB60Z]] || Dimmable LED bulb || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||Added as a dimmer rather than a light bulb||Jan 2015<br />
|-<br />
| Aeon Labs || [[DSB29-ZWUS|Door & Window Sensor - 2nd Edition]] || Door & Window Sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| Aeon Labs || [[DSC24-ZWUS|Plug-in Smart Appliance Switch]] || Power monitoring switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| GE/Jasco || [[GE 45609LAB|ZW4001/45609LAB]] || In-wall binary on/off switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| Remotec || [[Remotec ZDS-200|ZDS-200]] || Selectable plug-in dimmer/binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZFM-X10|ZFM-X10]] || Selectable in-wall dimmer/binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZRM-M80DE|ZRM-M80DE]] || Selectable plug-in dimmer/binary switch with CEE7/4 plug || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZRM-M80SA|ZRM-M80SA]] || Selectable plug-in dimmer/binary switch for South Africa || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Vision || [[Vision ZL-7431|ZL-7431]] || In-wall binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||Single relay only||Feb 2015<br />
|-<br />
| Vision || [[Vision ZL-7433|ZL-7433]] || In-wall dimmer || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Linear || [[Linear WD500Z-1|WD500Z-1]] || Hard Wired Wall Mount Dimmer Switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||March 2015<br />
|-<br />
| Vision || [[Vision ZG8101|ZG8101]] || Tilt/garage door sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink ECO-TILT-US|ECO-TILT-US]] || Tilt/garage door sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink PIRZWAVE2-ECO|PIRZWAVE2-ECO]] || PIR motion sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink DWZWAVE2-ECO|DWZWAVE2-ECO]] || Door/Window sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Leviton || [[Leviton DZS15-1L|Vizia rf+ DZS15-1L]] || Hard wired wall mounted switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Secure Together || [[Secure SRT321|SRT321]] || Set-point thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Utilitech || [[Utilitech TSE07-1|TSE07-1]] || Siren with Red Strobe/Flashing LED || [[File:Zwave.png]] - Z-Wave || Yes || No |||||June 2015<br />
|-<br />
| Everspring || [[AN180-6|AN180-6]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No || ON/OFF ||<br />
|-<br />
| Everspring || [[AD146|AD146]] || Switch || [[File:Zwave.png]] - Z-Wave || Yes || No || ON/OFF ||<br />
|-<br />
| Monoprice || [[11987|11987]] || Garage Door Sensor || [[File:Zwave.png]] - Z-Wave || Yes || No || ON/OFF ||</div>
SecureComp
https://wiki.securifi.com/index.php?title=Simple_Switch_App
Simple Switch App
2015-06-19T23:10:49Z
<p>SecureComp: added 2 more includes and complete switch.cpp file</p>
<hr />
<div>[[Category:Almond+ 2014]]<br />
The code in [[SDK_Setup_Guide_-_Almond+_2014]] for the sample switch app does not quite work as is, but the adjustment is fairly simple. Replace the main function with the following (note ~2 differences):<br />
<br />
switch.cpp:<br />
<code><pre><br />
main(int argc, char **argv) {<br />
<br />
HADevices::initialize();<br />
HADevices::genericCallback(&callback);<br />
<br />
if(argc <= 1 || argc >3)<br />
{<br />
//print usage<br />
fprintf(stderr, "usage: ./almond/switch Devid state\n");<br />
fprintf(stderr, " ./almond/switch <DevID> <1/0>\n");<br />
fprintf(stderr, "* example to turn on switch with DevId 2 : ./almond/switch 2 1\n");<br />
fprintf(stderr, "* go to device manager to see switch DevID ex: sensor #devid\n");<br />
fprintf(stderr, "* execute binary from / directory\n");<br />
return -1;<br />
}<br />
<br />
HADevices * ha = new HADevices;<br />
Device *sw;<br />
<br />
try {<br />
sw = ha->getDeviceByID(1);<br />
printf("Device %d found with name %s\n", sw->getID(), sw->getDeviceName());<br />
}catch (int exeption) {<br />
printf("No device found with that devid\n");<br />
return -1;<br />
}<br />
if(atoi(argv[2]))<br />
{<br />
fprintf(stderr, "Toggling switch on");<br />
sw->setSwitchOn(true);<br />
}<br />
else<br />
{<br />
fprintf(stderr, "Toggling switch off");<br />
sw->setSwitchOn(false);<br />
}<br />
<br />
while (1) {<br />
pause();<br />
}<br />
}<br />
</pre></code><br />
<br />
In order to resolve an "atoi" error during compile, add two more includes, stdio.h and stdlib.h.<br />
The complete modified switch.cpp file is shown below.<br />
<br />
<code><pre><br />
// add these 2 includes to avoid atoi error<br />
#include <stdio.h><br />
#include <stdlib.h><br />
<br />
#include <stdarg.h><br />
#include <iostream><br />
#include <string><br />
#include <string.h><br />
#include <fstream><br />
#include <sstream><br />
#include <sys/file.h><br />
#include <errno.h><br />
#include <fcntl.h><br />
#include <unistd.h><br />
#include <libAlmondHA.h><br />
<br />
void callback(Device* dev);<br />
//replace main proc with this new main proc from securifi wiki<br />
main(int argc, char **argv) {<br />
<br />
HADevices::initialize();<br />
HADevices::genericCallback(&callback);<br />
<br />
if(argc <= 1 || argc >3)<br />
{<br />
//print usage<br />
fprintf(stderr, "usage: ./almond/switch Devid state\n");<br />
fprintf(stderr, " ./almond/switch <DevID> <1/0>\n");<br />
fprintf(stderr, "* example to turn on switch with DevId 2 : ./almond/switch 2 1\n");<br />
fprintf(stderr, "* go to device manager to see switch DevID ex: sensor #devid\n");<br />
fprintf(stderr, "* execute binary from / directory\n");<br />
return -1;<br />
}<br />
<br />
HADevices * ha = new HADevices;<br />
Device *sw;<br />
<br />
try {<br />
sw = ha->getDeviceByID(1);<br />
printf("Device %d found with name %s\n", sw->getID(), sw->getDeviceName());<br />
}catch (int exeption) {<br />
printf("No device found with that devid\n");<br />
return -1;<br />
}<br />
if(atoi(argv[2]))<br />
{<br />
fprintf(stderr, "Toggling switch on");<br />
sw->setSwitchOn(true);<br />
}<br />
else<br />
{<br />
fprintf(stderr, "Toggling switch off");<br />
sw->setSwitchOn(false);<br />
}<br />
<br />
while (1) {<br />
pause();<br />
}<br />
}<br />
<br />
void callback(Device* dev) {<br />
fprintf(stderr, "Device Created Callback: %s\n",dev->getDeviceName());<br />
fprintf(stderr, "Index: %s, Value: %s\n", dev->getLastNotificationIndexName(), dev->getLastNotificationIndexValue());<br />
}<br />
<br />
<br />
</pre></code></div>
SecureComp
https://wiki.securifi.com/index.php?title=Utilitech_TSE07-1
Utilitech TSE07-1
2015-06-06T00:40:33Z
<p>SecureComp: </p>
<hr />
<div>'''Utilitech TSE07-1 Siren with Red Strobe/Flashing LED'''<br />
Z-Wave™ Compatible<br />
Sold at Lowes<br />
<br />
Identical to Everspring SE812<br />
<br />
Siren and Red Strobe ''triggered together''. No way to separate them yet, if ever.<br />
<br />
'''User selectable sound level''' via '''jumper pin''' inside battery compartment, '''100 or 90 decibels'''.<br />
<br />
Can be powered by '''battery or DC 6Volt source'''.<br />
<br />
User tested to work with Almond+<br />
<br />
<br />
<br />
'''PAIRING'''<br />
<br />
Install batteries in Utilitech Siren<br />
<br />
Place Almond+ in Z-Wave Add Sensor Mode<br />
<br />
Press Siren Test button until you hear beep (1 second), release Test button<br />
<br />
Complete Sensor Add dialog on Almond+<br />
<br />
<br />
'''RESET PAIRING'''<br />
<br />
If ''Pairing device to a different Hub'', you must perform a ''Reset by pressing the Pair Button (Test button) 8 times, one second apart''.<br />
<br />
Then proceed with standard Pairing instructions</div>
SecureComp
https://wiki.securifi.com/index.php?title=Utilitech_TSE07-1
Utilitech TSE07-1
2015-06-06T00:34:00Z
<p>SecureComp: </p>
<hr />
<div>'''Utilitech TSE07-1 Siren with Red Strobe/Flashing LED'''<br />
Z-Wave™ Compatible<br />
Sold at Lowes<br />
<br />
Identical to Everspring SE812<br />
<br />
Siren and Red Strobe ''triggered together''. No way to separate them yet, if ever.<br />
<br />
'''User selectable sound level''' via '''jumper pin''' inside battery compartment, '''100 or 90 decibels'''.<br />
<br />
Can be powered by '''battery or DC 6Volt source'''.<br />
<br />
User tested to work with Almond+<br />
<br />
<br />
<br />
'''PAIRING'''<br />
<br />
Install batteries in Utilitech Siren<br />
<br />
Place Almond+ in Z-Wave Add Sensor Mode<br />
<br />
Press Siren Test button until you hear beep (1 second), release Test button<br />
<br />
Complete Sensor Add dialog on Almond+</div>
SecureComp
https://wiki.securifi.com/index.php?title=List_of_compatible_sensors_-_Almond%2B_2014
List of compatible sensors - Almond+ 2014
2015-06-05T18:23:14Z
<p>SecureComp: /* Z-Wave */</p>
<hr />
<div>[[Category:Almond+ 2014]]<br />
[[Category:Sensors]]<br />
This is a lists of sensors and devices that are known to work with the [[Almond+ 2014]] and have been tested by Securifi, as well as sensors and devices tested by our customers and found to be working, but that haven't been verified by Securifi.<br /><br />
If you tried a device that is not listed, please let us know on the [http://forum.securifi.com/ forum].<br />
<br />
=== ZigBee ===<br />
<br />
{| class="wikitable sortable"<br />
|-<br />
! Manufacturer !! Model name !! Type !! Technology !! User tested !! Verified by Securifi !! Comments !! Date added <br />
|-<br />
| Securifi || [[Securifi SZ-DWS02|SZ-DWS02]] || Door/Window magnetic reed sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-PIR02|SZ-PIR02]] || PIR motion detector || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-BSW01|SZ-BSW01]] || Binary on/off plug-in switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Only provided to Kickstarter developer and beta backers||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-ESW01|SZ-ESW01]] || Power monitoring switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Only provided as a limited upgrade option to Kickstarter backers||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-WTD01|SZ-WTD01]] || Flood sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-KFB01|SZ-KFB01]] || Key fob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jun 2014<br />
|-<br />
| Securifi || [[Securifi Peanut Plug PP1-WHT-US|Peanut Plug]] || Power monitoring switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Note that the power monitoring will be added via an OTA firmware update||Jan 2015<br />
|-<br />
| Osram/Sylvania || [[Osram_Sylvania Ultra iQ|Ultra iQ]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||May 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SGB02|WZB-SGB02]] || Vibration sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SMG02|WZB-SMG02]] || Door/Window magnetic reed sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SSM706|WZB-SSM706]] || Smoke detector || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Fortrezz || [[SmartSense Moisture|SmartSense Moisture]] || Moisture sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||<br />
|-<br />
| GE || [[GE/Wink Link bulbs|GE/Wink Link bulbs]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||<br />
|-<br />
| SmartThings || [[SmartThings SmartSense Multi Sensor|SmartSense Multi Sensor]] || Door/Window multi sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Trigger the sensor once to make it connect to the Almond+ during the adding process||<br />
|-<br />
| Belkin || [[WeMo Smart LED bulb|WeMo Smart LED bulb]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2015<br />
|-<br />
| Philips || [[Philips hue hub|hue hub]] || hue light hub || [[File:Zigb.png]] - ZigBee || Yes || Yes ||The hub has to be paired with the Almond+ to control the bulbs though the Almond app||Feb 2015<br />
|-<br />
| Cree || [[Cree Connected Smart Bulb|Cree Connected Smart Bulb]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || No ||Home Depot exclusive||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Door & Window Sensor|CentraLite 3-Series Door & Window Sensor]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Water Sensors|CentraLite 3-Series Water Sensors]] || Flood sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Temp and Humidity Sensor|CentraLite 3-Series Temp & Humidity Sensor]] || Temperature and humidity sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq. Note that humidity sensing is currently unsupported||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Motion Sensor|CentraLite 3-Series Motion Sensor]] || Motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq. ||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3011|NCZ-3011]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3014|NCZ-3014]] || Garage Door (Tilt) Sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3041|NCZ-3041]] || Motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3043|NCZ-3043]] || Ceiling motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3202|NCZ-3202]] || Lifestyle automation keyfob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3201|NCZ-3201]] || Access control keyfob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Classic A60 RGBW|Lightify Classic A60 RGBW]] || RGBW LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Classic A60 tunable white|Lightify Classic A60 tunable white]] || Tunable white LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify PAR16 50 tunable white|Lightify PAR16 50 tunable white]] || Tunable white LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Surface light tunable white|Lightify Surface light tunable white]] || Tunable white LED light || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Quirky/GE || [[Quirky PTRPR-WH01|Quirky + GE Tripper]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Quirky/GE || [[Quirky PTAPT-WH02|Quirky + GE Tapt ]] || Smart wall switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Yale || [[Yale YRD-220-HA-619|YRD-220-HA-619]] || Deadbolt Lock || [[File:Zigb.png]] - ZigBee || Yes || Yes || Only lock/unlock ||<br />
|-<br />
| Everspring || [[AN180-6|AN180-6]] || Binary on/off plug-in switch || [[File:Zigb.png]] - ZigBee || No || Yes || ON/OFF ||<br />
|-<br />
| Everspring || [[AD146|AD146]] || Switch || [[File:Zigb.png]] - ZigBee || No || Yes || ON/OFF ||<br />
|}<br />
<br />
=== Z-Wave ===<br />
<br />
{| class="wikitable sortable"<br />
|-<br />
! Manufacturer !! Model name !! Type !! Technology !! User tested !! Verified by Securifi !! Comments !! Date added <br />
|-<br />
| Vision || [[Vision ZD2102|ZD2102]] || Door/Window magnetic reed sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZL7201|ZL7201]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZL7101|ZL7101]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZM1701|ZM1701]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision ZM1702|ZM1702]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ5101|ZS5101]] || Shock sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ3102|ZS3102]] || PIR motion sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ6101|ZS6101]] || Smoke Detector || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Fibaro || [[Fibaro FGK-101-107]] || Door/Window sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes || No extra features ||<br />
|-<br />
| Fibaro || [[Fibaro FGWPE/F-101]] || Wall plug || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only On/Off and power reading ||<br />
|-<br />
| Fibaro || [[Fibaro FGFS-101]] || Flood sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only flood alert so far ||<br />
|-<br />
| Yale || [[Yale YRD210|YRD210]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Schlage || [[Schlage FE599|FE599]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Schlage || [[Schlage BE369|BE369]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || No || Only lock/unlock & user code ||<br />
|-<br />
| Lowe's Iris || [[Lowe's Iris CT100|CT100]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Lowe's Iris || [[Lowe's Iris CT101|CT101]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| 2Gig Technologies || [[2Gig Technologies CT30|CT30]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| 2Gig Technologies || [[2Gig Technologies RTZW-01|RTZW-01]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| First Alert || [[First Alert Smoke & CO Detectors|ZSMOKE]] || Smoke Detector || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| First Alert || [[First Alert Smoke & CO Detectors|ZCOMBO]] || Smoke and CO Detector || [[File:Zwave.png]] - Z-Wave || Yes || No || CO events may not be shown ||<br />
|-<br />
| Poly-Control || [[Poly-Control Danalock|Danalock]] || Door lock ||[[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock ||<br />
|-<br />
| Intermatic Home Settings || [[HA01]] || In-Wall receptacle || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring AN158|AN158]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring AD142|AD142]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring ST812|ST812]] || Flood sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring SE812|SE812]] || Siren with Red Strobe/Flashing LED|| [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| GE/Jasco || [[GE 45603|ZW4101/45603]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| GE/Jasco || [[GE 45604|45604]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes || For Outdoors use ||<br />
|-<br />
| GE || [[GE ZW3101|ZW3101]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Remotec || [[Remotec ZDS-100|ZDS-100]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Remotec || [[Remotec ZFM-80|ZFM-80]] || Binary on/off switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Trane || [[Trane TZEMT400BB3NX|TZEMT400BB3NX ]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| GE || [[GE 45605|GE 45605]] || Duplex Receptacle || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Yale || [[Yale YRD220-ZW-ORB|YRD220-ZW-ORB]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || No || Only lock/unlock & user code ||<br />
|-<br />
| Jasco || [[Jasco 45609|45609]] || Wireless Lighting Control On/Off Switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Leviton || [[Leviton VRS15-1LZ Vizia RF|VRS15-1LZ Vizia RF]] || Binary on/off light switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Intermatic || [[HomeSettings HA05|HA05]] || Binary on/off Screw-In Lamp module || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Kwikset || [[Kwikset 910TRL ZW|Kwikset 910TRL ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Kwikset || [[Kwikset 910CNT ZW|Kwikset 910CNT ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Kwikset || [[Kwikset 914TRL ZW|Kwikset 914TRL ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Danfoss || [[Living Connect LC-13|Living Connect LC-13]] || Setpoint radiator thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Nov 2014<br />
|-<br />
| Linear/LinearLinc || [[Linear Bulbz LB60Z|Bulbz LB60Z]] || Dimmable LED bulb || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||Added as a dimmer rather than a light bulb||Jan 2015<br />
|-<br />
| Aeon Labs || [[DSB29-ZWUS|Door & Window Sensor - 2nd Edition]] || Door & Window Sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| Aeon Labs || [[DSC24-ZWUS|Plug-in Smart Appliance Switch]] || Power monitoring switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| GE/Jasco || [[GE 45609LAB|ZW4001/45609LAB]] || In-wall binary on/off switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| Remotec || [[Remotec ZDS-200|ZDS-200]] || Selectable plug-in dimmer/binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZFM-X10|ZFM-X10]] || Selectable in-wall dimmer/binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZRM-M80DE|ZRM-M80DE]] || Selectable plug-in dimmer/binary switch with CEE7/4 plug || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZRM-M80SA|ZRM-M80SA]] || Selectable plug-in dimmer/binary switch for South Africa || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Vision || [[Vision ZL-7431|ZL-7431]] || In-wall binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||Single relay only||Feb 2015<br />
|-<br />
| Vision || [[Vision ZL-7433|ZL-7433]] || In-wall dimmer || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Linear || [[Linear WD500Z-1|WD500Z-1]] || Hard Wired Wall Mount Dimmer Switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||March 2015<br />
|-<br />
| Vision || [[Vision ZG8101|ZG8101]] || Tilt/garage door sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink ECO-TILT-US|ECO-TILT-US]] || Tilt/garage door sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink PIRZWAVE2-ECO|PIRZWAVE2-ECO]] || PIR motion sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink DWZWAVE2-ECO|DWZWAVE2-ECO]] || Door/Window sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Leviton || [[Leviton DZS15-1L|Vizia rf+ DZS15-1L]] || Hard wired wall mounted switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Secure Together || [[Secure SRT321|SRT321]] || Set-point thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Utilitech || [[Utilitech TSE07-1|TSE07-1]] || Siren with Red Strobe/Flashing LED || [[File:Zwave.png]] - Z-Wave || Yes || No |||||June 2015</div>
SecureComp
https://wiki.securifi.com/index.php?title=Utilitech_TSE07-1
Utilitech TSE07-1
2015-06-05T18:12:28Z
<p>SecureComp: </p>
<hr />
<div>'''Utilitech TSE07-1 Siren with Red Strobe/Flashing LED'''<br />
Z-Wave™ Compatible<br />
Sold at Lowes<br />
<br />
Identical to Everspring SE812<br />
<br />
Siren and Red Strobe ''triggered together''. No way to separate them yet, if ever.<br />
<br />
'''User selectable sound level''' via '''jumper pin''' inside battery compartment, '''100 or 80 decibels'''.<br />
<br />
Can be powered by '''battery or DC 6Volt source'''.<br />
<br />
User tested to work with Almond+<br />
<br />
<br />
<br />
'''PAIRING'''<br />
<br />
Install batteries in Utilitech Siren<br />
<br />
Place Almond+ in Z-Wave Add Sensor Mode<br />
<br />
Press Siren Test button until you hear beep (1 second), release Test button<br />
<br />
Complete Sensor Add dialog on Almond+</div>
SecureComp
https://wiki.securifi.com/index.php?title=Utilitech_TSE07-1
Utilitech TSE07-1
2015-06-05T18:08:44Z
<p>SecureComp: </p>
<hr />
<div>Utilitech TSE07-1 Siren with Red Strobe/Flashing LED<br />
Z-Wave™ Compatible<br />
Sold at Lowes<br />
<br />
Identical to Everspring SE812<br />
<br />
Siren and Red Strobe triggered together. No way to separate them yet, if ever.<br />
<br />
User selectable sound level via jumper pin inside battery compartment, 100 or 80 decibels.<br />
<br />
Can be powered by battery or DC 6Volt source.<br />
<br />
User tested to work with Almond+<br />
<br />
PAIRING<br />
<br />
Install batteries in Utilitech Siren<br />
Place Almond+ in Z-Wave Add Sensor Mode<br />
Press Siren Test button until you hear beep (1 second), release Test button<br />
Complete Sensor Add dialog on Almond+</div>
SecureComp
https://wiki.securifi.com/index.php?title=Utilitech_TSE07-1
Utilitech TSE07-1
2015-06-05T18:06:46Z
<p>SecureComp: Utilitech TSE07-1 Siren details</p>
<hr />
<div>Utilitech TSE07-1 Siren with Red Strobe/Flashing LED<br />
Z-Wave™ Compatible<br />
Sold at Lowes<br />
<br />
Identical to Everspring SE812<br />
<br />
Siren and Red Strobe triggered together. No way to separate them yet, if ever.<br />
<br />
User selectable sound level via jumper pin inside battery compartment, 100 or 80 decibels.<br />
<br />
Can be powered by battery or DC 6Volt source.<br />
<br />
User tested to work with Almond+</div>
SecureComp
https://wiki.securifi.com/index.php?title=List_of_compatible_sensors_-_Almond%2B_2014
List of compatible sensors - Almond+ 2014
2015-06-05T17:59:08Z
<p>SecureComp: Added Utilitech Siren sensor - user tested</p>
<hr />
<div>[[Category:Almond+ 2014]]<br />
[[Category:Sensors]]<br />
This is a lists of sensors and devices that are known to work with the [[Almond+ 2014]] and have been tested by Securifi, as well as sensors and devices tested by our customers and found to be working, but that haven't been verified by Securifi.<br /><br />
If you tried a device that is not listed, please let us know on the [http://forum.securifi.com/ forum].<br />
<br />
=== ZigBee ===<br />
<br />
{| class="wikitable sortable"<br />
|-<br />
! Manufacturer !! Model name !! Type !! Technology !! User tested !! Verified by Securifi !! Comments !! Date added <br />
|-<br />
| Securifi || [[Securifi SZ-DWS02|SZ-DWS02]] || Door/Window magnetic reed sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-PIR02|SZ-PIR02]] || PIR motion detector || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-BSW01|SZ-BSW01]] || Binary on/off plug-in switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Only provided to Kickstarter developer and beta backers||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-ESW01|SZ-ESW01]] || Power monitoring switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Only provided as a limited upgrade option to Kickstarter backers||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-WTD01|SZ-WTD01]] || Flood sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2014<br />
|-<br />
| Securifi || [[Securifi SZ-KFB01|SZ-KFB01]] || Key fob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jun 2014<br />
|-<br />
| Securifi || [[Securifi Peanut Plug PP1-WHT-US|Peanut Plug]] || Power monitoring switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Note that the power monitoring will be added via an OTA firmware update||Jan 2015<br />
|-<br />
| Osram/Sylvania || [[Osram_Sylvania Ultra iQ|Ultra iQ]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||May 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SGB02|WZB-SGB02]] || Vibration sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SMG02|WZB-SMG02]] || Door/Window magnetic reed sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Nietzsche Enterprise || [[Nietzsche Enterprise WZB-SSM706|WZB-SSM706]] || Smoke detector || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Apr 2014<br />
|-<br />
| Fortrezz || [[SmartSense Moisture|SmartSense Moisture]] || Moisture sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||<br />
|-<br />
| GE || [[GE/Wink Link bulbs|GE/Wink Link bulbs]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||<br />
|-<br />
| SmartThings || [[SmartThings SmartSense Multi Sensor|SmartSense Multi Sensor]] || Door/Window multi sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Trigger the sensor once to make it connect to the Almond+ during the adding process||<br />
|-<br />
| Belkin || [[WeMo Smart LED bulb|WeMo Smart LED bulb]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||Jan 2015<br />
|-<br />
| Philips || [[Philips hue hub|hue hub]] || hue light hub || [[File:Zigb.png]] - ZigBee || Yes || Yes ||The hub has to be paired with the Almond+ to control the bulbs though the Almond app||Feb 2015<br />
|-<br />
| Cree || [[Cree Connected Smart Bulb|Cree Connected Smart Bulb]] || Dimmable LED bulb || [[File:Zigb.png]] - ZigBee || Yes || No ||Home Depot exclusive||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Door & Window Sensor|CentraLite 3-Series Door & Window Sensor]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Water Sensors|CentraLite 3-Series Water Sensors]] || Flood sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Temp and Humidity Sensor|CentraLite 3-Series Temp & Humidity Sensor]] || Temperature and humidity sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq. Note that humidity sensing is currently unsupported||March 2015<br />
|-<br />
| CentraLite || [[CentraLite 3-Series Motion Sensor|CentraLite 3-Series Motion Sensor]] || Motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||Branded by SmartThings and Peq. ||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3011|NCZ-3011]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3014|NCZ-3014]] || Garage Door (Tilt) Sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3041|NCZ-3041]] || Motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3043|NCZ-3043]] || Ceiling motion sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3202|NCZ-3202]] || Lifestyle automation keyfob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| NYCE || [[NYCE NCZ-3201|NCZ-3201]] || Access control keyfob || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Classic A60 RGBW|Lightify Classic A60 RGBW]] || RGBW LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Classic A60 tunable white|Lightify Classic A60 tunable white]] || Tunable white LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify PAR16 50 tunable white|Lightify PAR16 50 tunable white]] || Tunable white LED light bulb || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Osram || [[Lightify Surface light tunable white|Lightify Surface light tunable white]] || Tunable white LED light || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Quirky/GE || [[Quirky PTRPR-WH01|Quirky + GE Tripper]] || Door/Window sensor || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Quirky/GE || [[Quirky PTAPT-WH02|Quirky + GE Tapt ]] || Smart wall switch || [[File:Zigb.png]] - ZigBee || Yes || Yes ||||March 2015<br />
|-<br />
| Yale || [[Yale YRD-220-HA-619|YRD-220-HA-619]] || Deadbolt Lock || [[File:Zigb.png]] - ZigBee || Yes || Yes || Only lock/unlock ||<br />
|-<br />
| Everspring || [[AN180-6|AN180-6]] || Binary on/off plug-in switch || [[File:Zigb.png]] - ZigBee || No || Yes || ON/OFF ||<br />
|-<br />
| Everspring || [[AD146|AD146]] || Switch || [[File:Zigb.png]] - ZigBee || No || Yes || ON/OFF ||<br />
|}<br />
<br />
=== Z-Wave ===<br />
<br />
{| class="wikitable sortable"<br />
|-<br />
! Manufacturer !! Model name !! Type !! Technology !! User tested !! Verified by Securifi !! Comments !! Date added <br />
|-<br />
| Vision || [[Vision ZD2102|ZD2102]] || Door/Window magnetic reed sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZL7201|ZL7201]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZL7101|ZL7101]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2014<br />
|-<br />
| Vision || [[Vision ZM1701|ZM1701]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision ZM1702|ZM1702]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ5101|ZS5101]] || Shock sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ3102|ZS3102]] || PIR motion sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Vision || [[Vision SZ6101|ZS6101]] || Smoke Detector || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Fibaro || [[Fibaro FGK-101-107]] || Door/Window sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes || No extra features ||<br />
|-<br />
| Fibaro || [[Fibaro FGWPE/F-101]] || Wall plug || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only On/Off and power reading ||<br />
|-<br />
| Fibaro || [[Fibaro FGFS-101]] || Flood sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only flood alert so far ||<br />
|-<br />
| Yale || [[Yale YRD210|YRD210]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Schlage || [[Schlage FE599|FE599]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Schlage || [[Schlage BE369|BE369]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || No || Only lock/unlock & user code ||<br />
|-<br />
| Lowe's Iris || [[Lowe's Iris CT100|CT100]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Lowe's Iris || [[Lowe's Iris CT101|CT101]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| 2Gig Technologies || [[2Gig Technologies CT30|CT30]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| 2Gig Technologies || [[2Gig Technologies RTZW-01|RTZW-01]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| First Alert || [[First Alert Smoke & CO Detectors|ZSMOKE]] || Smoke Detector || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| First Alert || [[First Alert Smoke & CO Detectors|ZCOMBO]] || Smoke and CO Detector || [[File:Zwave.png]] - Z-Wave || Yes || No || CO events may not be shown ||<br />
|-<br />
| Poly-Control || [[Poly-Control Danalock|Danalock]] || Door lock ||[[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock ||<br />
|-<br />
| Intermatic Home Settings || [[HA01]] || In-Wall receptacle || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring AN158|AN158]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring AD142|AD142]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring ST812|ST812]] || Flood sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Everspring || [[Everspring SE812|SE812]] || Siren with Red Flashing LED|| [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| GE/Jasco || [[GE 45603|ZW4101/45603]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| GE/Jasco || [[GE 45604|45604]] || Binary on/off plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes || For Outdoors use ||<br />
|-<br />
| GE || [[GE ZW3101|ZW3101]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Remotec || [[Remotec ZDS-100|ZDS-100]] || Dimmer plug-in switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Remotec || [[Remotec ZFM-80|ZFM-80]] || Binary on/off switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Trane || [[Trane TZEMT400BB3NX|TZEMT400BB3NX ]] || Thermostat || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| GE || [[GE 45605|GE 45605]] || Duplex Receptacle || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Yale || [[Yale YRD220-ZW-ORB|YRD220-ZW-ORB]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || No || Only lock/unlock & user code ||<br />
|-<br />
| Jasco || [[Jasco 45609|45609]] || Wireless Lighting Control On/Off Switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Leviton || [[Leviton VRS15-1LZ Vizia RF|VRS15-1LZ Vizia RF]] || Binary on/off light switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||<br />
|-<br />
| Intermatic || [[HomeSettings HA05|HA05]] || Binary on/off Screw-In Lamp module || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Kwikset || [[Kwikset 910TRL ZW|Kwikset 910TRL ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Kwikset || [[Kwikset 910CNT ZW|Kwikset 910CNT ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Kwikset || [[Kwikset 914TRL ZW|Kwikset 914TRL ZW]] || Deadbolt Lock || [[File:Zwave.png]] - Z-Wave || Yes || Yes || Only lock/unlock & user code ||<br />
|-<br />
| Danfoss || [[Living Connect LC-13|Living Connect LC-13]] || Setpoint radiator thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Nov 2014<br />
|-<br />
| Linear/LinearLinc || [[Linear Bulbz LB60Z|Bulbz LB60Z]] || Dimmable LED bulb || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||Added as a dimmer rather than a light bulb||Jan 2015<br />
|-<br />
| Aeon Labs || [[DSB29-ZWUS|Door & Window Sensor - 2nd Edition]] || Door & Window Sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| Aeon Labs || [[DSC24-ZWUS|Plug-in Smart Appliance Switch]] || Power monitoring switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| GE/Jasco || [[GE 45609LAB|ZW4001/45609LAB]] || In-wall binary on/off switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Jan 2015<br />
|-<br />
| Remotec || [[Remotec ZDS-200|ZDS-200]] || Selectable plug-in dimmer/binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZFM-X10|ZFM-X10]] || Selectable in-wall dimmer/binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZRM-M80DE|ZRM-M80DE]] || Selectable plug-in dimmer/binary switch with CEE7/4 plug || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Remotec || [[Remotec ZRM-M80SA|ZRM-M80SA]] || Selectable plug-in dimmer/binary switch for South Africa || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Vision || [[Vision ZL-7431|ZL-7431]] || In-wall binary switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||Single relay only||Feb 2015<br />
|-<br />
| Vision || [[Vision ZL-7433|ZL-7433]] || In-wall dimmer || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||Feb 2015<br />
|-<br />
| Linear || [[Linear WD500Z-1|WD500Z-1]] || Hard Wired Wall Mount Dimmer Switch || [[File:Zwave.png]] - Z-Wave || Yes || No ||||March 2015<br />
|-<br />
| Vision || [[Vision ZG8101|ZG8101]] || Tilt/garage door sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink ECO-TILT-US|ECO-TILT-US]] || Tilt/garage door sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink PIRZWAVE2-ECO|PIRZWAVE2-ECO]] || PIR motion sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Ecolink || [[Ecolink DWZWAVE2-ECO|DWZWAVE2-ECO]] || Door/Window sensor || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Leviton || [[Leviton DZS15-1L|Vizia rf+ DZS15-1L]] || Hard wired wall mounted switch || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||March 2015<br />
|-<br />
| Secure Together || [[Secure SRT321|SRT321]] || Set-point thermostat || [[File:Zwave.png]] - Z-Wave || Yes || Yes ||||<br />
|-<br />
| Utilitech || [[Utilitech TSE07-1|TSE07-1]] || Siren with Red Flashing LED || [[File:Zwave.png]] - Z-Wave || Yes || No |||||June 2015</div>
SecureComp
https://wiki.securifi.com/index.php?title=Everspring_SE812
Everspring SE812
2015-06-05T17:51:36Z
<p>SecureComp: Created page with "Siren that is Z-Wave™ compatible. User selectable Siren Level Adjustment via jumper pin. Manufacturer product website http://www.everspring.com/SE812.aspx"</p>
<hr />
<div>Siren that is Z-Wave™ compatible.<br />
User selectable Siren Level Adjustment via jumper pin.<br />
<br />
Manufacturer product website http://www.everspring.com/SE812.aspx</div>
SecureComp