Difference between revisions of "First Alert Smoke & CO Detectors"

From SecuriWiki
Jump to: navigation, search
(Created page with "== From First Alert Manual == • The alarm will operate with 3rd party, certified Z-Wave devices. Basic command class required by all Z-Wave devices. By the requirements of t...")
 
 
(One intermediate revision by one user not shown)
Line 5: Line 5:
 
to any particular functionality for this device.
 
to any particular functionality for this device.
  
== INCLUSION ==
+
== Inclusion/Adding ==
 
# Slide battery door open.
 
# Slide battery door open.
 
# Insert batteries checking the correct orientation.
 
# Insert batteries checking the correct orientation.
 
# Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button.
 
# Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button.
  
== EXCLUSION ==
+
== Exclusion/Removing ==
 
# Slide battery door open.
 
# Slide battery door open.
 
# Remove and re-insert batteries checking the correct orientation.
 
# Remove and re-insert batteries checking the correct orientation.
Line 18: Line 18:
 
* The alarm supports configuration parameter #1, which has a size of 1, a default value of 0, and when set to 1 causes the device to send double alarm messages.
 
* The alarm supports configuration parameter #1, which has a size of 1, a default value of 0, and when set to 1 causes the device to send double alarm messages.
  
== RESET DEVICE ==
+
== Resetting the device ==
 
If the device is powered up with the test button held down for 10+ seconds, the device will reset all Z-Wave settings and leave the network. NOTE: The device
 
If the device is powered up with the test button held down for 10+ seconds, the device will reset all Z-Wave settings and leave the network. NOTE: The device
 
will not remain awake after resetting and will go into standby mode.
 
will not remain awake after resetting and will go into standby mode.

Latest revision as of 05:55, 12 January 2015

From First Alert Manual

• The alarm will operate with 3rd party, certified Z-Wave devices. Basic command class required by all Z-Wave devices. By the requirements of the Device Class spec, this command class does not have to be mapped to any particular functionality for this device.

Inclusion/Adding

  1. Slide battery door open.
  2. Insert batteries checking the correct orientation.
  3. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button.

Exclusion/Removing

  1. Slide battery door open.
  2. Remove and re-insert batteries checking the correct orientation.
  3. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button.
  • The alarm will remain awake for 30 seconds on inclusion.
  • The alarm supports one association group with up to 5 nodes, and sends its alarms to that group.
  • The alarm supports configuration parameter #1, which has a size of 1, a default value of 0, and when set to 1 causes the device to send double alarm messages.

Resetting the device

If the device is powered up with the test button held down for 10+ seconds, the device will reset all Z-Wave settings and leave the network. NOTE: The device will not remain awake after resetting and will go into standby mode.